Duryn One cartridge / Testing & transparency

Clear water.
Clear answers.

Explore the evidence behind the cartridge. Organised by what matters to you.

Duryn One glass pitcher, stainless steel funnel, cartridge and drinking glass
Glass. Steel. Thoughtful details.
08Contaminant groups.
Easy to explore.
12Source measurements.
Linked to the evidence.
42 / 372NSF Certified.
Scope explained.
The results, by category

What’s in your water?
Start here.

Search a name or open a group. Published source results and entries awaiting evidence are labelled separately.

Testing continues.
Results shared.

We continue testing the Duryn One cartridge with IAPMO and other labs, including against relevant (European Union) EN 17093 requirements. New results are published here with links to the full reports.

Read the source details
Explore a group

Chlorine & disinfectants

3 topics · 3 published source results
Source report available

Duryn One cartridge is independently tested to reduce chlorine, helping improve the taste and odour of your tap water. Explore the results below.

Chlorine
Free chlorine
99.99%Source result
Chloramine
Combined chlorine
98.88%Source result
Chlorine dioxide
99.98%Source result
How these results were measured
IAPMO IndiaNSF/ANSI 42375 L

The final table entry reports an influent concentration of 2.0 mg/L and an effluent concentration of <0.1 mg/L. Calculated reduction: 99%+.

Recorded rows throughout the test range from approximately 99.4% to 99.99% reduction. The tested sample is carbon filter.

12 September 2026 · Ref. 20545A/25-26

Read the full source report

PFAS & forever chemicals

14 topics · 8 published source results
Source report available

Seven PFAS compounds are measured individually in the source report. Each percentage below is a conservative minimum calculated from the laboratory reporting limit.

PFOA
Perfluorooctanoic acid
>98.96%Source result
PFOS
Perfluorooctanesulfonic acid
>99.49%Source result
PFHxS
Perfluorohexanesulfonic acid
>98.44%Source result
PFNA
Perfluorononanoic acid
>99.63%Source result
PFHpA
Perfluoroheptanoic acid
>97.59%Source result
PFBS
Perfluorobutanesulfonic acid
>98.13%Source result
PFDA
Perfluorodecanoic acid
>99.09%Source result
PFBA
Perfluorobutanoic acid
>99.97%Source result
PFPeA
Perfluoropentanoic acid
No published result
PFHxA
Perfluorohexanoic acid
No published result
PFUnDA
Perfluoroundecanoic acid · PFUnA
No published result
PFDoDA
Perfluorododecanoic acid · PFDoA
No published result
HFPO-DA
GenX
No published result
ADONA
4,8-Dioxa-3H-perfluorononanoic acid
No published result
How these results were measured
IAPMO IndiaNSF/ANSI 5335 L table

The influent values are PFOA 485, PFOS 985, PFHxS 321.1, PFNA 53.4, PFHpA 40.3, PFBS 268.3 and PFDA 8.21 ppt. Every individual effluent value is reported as <5 ppt.

Minimum calculated reduction = (1 − reporting limit ÷ measured influent) × 100. Displayed minimums are rounded down, not up. No fixed 99.5% reduction is assigned to every PFAS compound.

23 September 2025 · Ref. 20545-C/25-26

Read the full source report

Lead & heavy metals

12 topics · 4 published source results
Source report available

Lead, cadmium and mercury have source measurements. Each other metal is listed separately so future results can be added without implying broader coverage.

Lead
Pb
>96.42%Source result
Cadmium
Cd
>98.85%Source result
Mercury
Hg
>99.13%Source result
Arsenic
As
>99.98%Source result
Copper
Cu
No published result
Hexavalent chromium
Chromium VI · Cr(VI)
No published result
Trivalent chromium
Chromium III · Cr(III)
No published result
Nickel
Ni
No published result
Aluminium
Aluminum · Al
No published result
Selenium
Se
No published result
Uranium
U
No published result
Manganese
Mn
No published result
How these results were measured
IAPMONSF/ANSI 53

 Lead is 0.140 → <0.005 mg/L, cadmium is 0.028 → <0.002 mg/L and mercury is 0.0053 → <0.001 mg/L. The greater-than percentages are calculated using those reporting limits.

Its tested volume should not be replaced with the cartridge replacement interval.

23 September 2026 · Ref. 20545D/25-26

Read the full source report

VOCs & solvents

18 topics · 18 published source results
Source report available

A place for individual VOC results and a clearly identified surrogate test, when supported by a dedicated reduction report.

Chloroform
Potential VOC surrogate; report required
>99.98%Source result
Benzene
Based on surogate
>99%Source result
Ethylbenzene
>99%Source result
Toluene
>99%Source result
Xylenes
Total xylenes
>99%Source result
Trichloroethylene
TCE
>99%Source result
Tetrachloroethylene
PCE · perchloroethylene
>99%Source result
Carbon tetrachloride
>99%Source result
Chlorobenzene
>99%Source result
1,2-Dichloroethane
>99%Source result
1,1-Dichloroethylene
>99%Source result
cis-1,2-Dichloroethylene
>99%Source result
trans-1,2-Dichloroethylene
>99%Source result
1,2-Dichloropropane
>99%Source result
1,2,4-Trichlorobenzene
>99%Source result
1,1,1-Trichloroethane
>99%Source result
1,1,2-Trichloroethane
>99%Source result
Styrene
>99%Source result

The results are based on VOC surrogate testing. This testing uses a representative compound to assess removal performance under the tested conditions.

Pesticides & herbicides

13 topics · 0 published source results
More evidence to add

Individual agricultural chemicals, with an editable entry for each future laboratory result.

Atrazine
No published result
Alachlor
No published result
Simazine
No published result
Lindane
No published result
2,4-D
No published result
Carbofuran
No published result
Heptachlor
No published result
Heptachlor epoxide
No published result
Endrin
No published result
Methoxychlor
No published result
Chloropicrin
No published result
Dinoseb
No published result
Glyphosate
No published result

No reduction result is published for these entries. A future VOC surrogate report may support only the chemicals and claim conditions that it explicitly covers.

Pharmaceuticals & emerging compounds

15 topics · 0 published source results
More evidence to add

Medicines, hormones and other emerging compounds are grouped together for easy reference. Their presence here is not a reduction claim.

Bisphenol A
BPA
No published result
Estrone
No published result
Ibuprofen
No published result
Naproxen
No published result
Phenytoin
No published result
Nonylphenol
No published result
Atenolol
No published result
Carbamazepine
No published result
Meprobamate
No published result
Metolachlor
No published result
Trimethoprim
No published result
DEET
No published result
Linuron
No published result
TCEP
Tris(2-chloroethyl) phosphate
No published result
TCPP
Tris(1-chloro-2-propyl) phosphate
No published result

No published reduction results are attached to this group. Each row is ready for its own measured result or an explicitly supported group claim.

Particles, cysts & microbes

5 topics · 3 published source results
Source report available

The source report tests a cyst surrogate. Microplastics, finer particulates, bacteria and viruses require their own evidence.

Cyst surrogate
3 µm microspheres
Conservative display; report records 99.9%.
99.5%+Source result
Microplastics
0.5–1.0 µm test size
>99.89%Source result
Particulate Class I
0.5–1.0 µm particles
>99%Source result
Bacteria
Including E. coli
Not claimed
Viruses
Not claimed
How these results were measured
IAPMO IndiaNSF P231 referenceSingle reported challenge

The reported challenge is 52,400 three-micron microspheres per litre, with an effluent count of <20 per litre. The laboratory records 99.9% reduction and LRV 3.41.

The displayed 99.5%+ is deliberately conservative. This is a microsphere surrogate result, not a live-organism test or a microplastic test at 0.5–1.0 µm.

19 September 2025 · Ref. 20546/24-25

Read the full source report

Fluoride & dissolved substances

6 topics · 1 published source results
Source report available

These entries make the current claim limits explicit and leave space for future product-specific documentation.

Fluoride
Duryn One cartridge
>82%Source result
Nitrate
NO₃⁻
No published result
Nitrite
NO₂⁻
No published result
New contaminant
No published result
Water hardness
Calcium and magnesium · limescale
Not claimed
Total dissolved solids
TDS
Not claimed

Duryn One reduces fluoride by >82%. No softening or TDS-removal claim is made here.

“>” means greater than the displayed value. Values based on a laboratory reporting limit are minimum calculated reductions, not exact measurements. “No published result” is not a removal claim or a promise that testing is underway.

Material choices, inside and out

Steel, down to
the end caps.

The Duryn One cartridge uses solid medical-grade 316L stainless steel end caps instead of plastic. Our choice of materials goes beyond the glass pitcher and stainless steel funnel.

NSF CERTIFICATION

Certified at the core.

Certification documents and contaminant-reduction tests answer different questions. Here is what each document covers.

42

Material safety.
Structural integrity.

The current NSF listing covers the carbon-block component of our water filter cartridge. Tested for helping reduce chlorine-related taste and odour.

Certificate holder: Salvi Line Ltd
Certificate C0876429-01 · 17 September 2025
372

Lead Free Certified.
Water-contact materials.

The carbon block in the Duryn One cartridge meets NSF/ANSI/CAN 372 certification requirements for lead-free materials.

Certificate holder: Salvi Line Ltd
Combined certificate C0876429-01 · 17 September 2025

The NSF certificates cover the carbon block inside the Duryn One pitcher’s cartridge.

The original documents

The evidence.
One click away.

Request a test report
Original laboratory PDF

Chlorine reduction

IAPMO India
12 September 2026
Ref. 20545A/24-25
NSF/ANSI 42

View full report
Original laboratory PDF

PFAS reduction

IAPMO India
23 September 2026
Ref. 20545-C/25-26
NSF/ANSI 53

View full report
Original laboratory PDF

Lead & heavy metals

IAPMO India
23 September 2026
Ref. 20545D/25-26
NSF/ANSI 53

View full report
Original laboratory PDF

Cyst-surrogate test

IAPMO India
19 September 2026
Ref. 20546/24-25
NSF P231 reference

View full report
Source names, conditions and product correspondence

All product references on this page use Duryn One cartridge. The published laboratories’ reports retain their original submitted sample names. Product-to-report correspondence must be documented before these source measurements are presented as verified Duryn One performance.

  • Chlorine: Salvi Line Ltd “Carbon Filter”, IAPMO 20545A/24-25. The displayed 95% is calculated from the final 300 L row; other recorded rows range from approximately 94.4% to 95.2%.
  • PFAS: Salvi Line Ltd “Carbon Filters”, IAPMO 20545-C/25-26. Individual values use the 35 L table. Effluent is reported as <5 ppt for each of seven compounds. Although one narrative mentions 100 L, the published data table ends at 35 L.
  • Metals: Salvi Line Ltd “Stainless Steel Tank with Carbon block”, IAPMO 20545D/25-26. Values use the 50 L table. The report notes declining flow.
  • Cyst surrogate: Salvi Line Ltd “Carbon Filter”, IAPMO 20546/24-25. The test uses 3 µm microspheres. The report records 99.9%; this page displays a conservative 99.5%+. This does not establish microplastic, bacteria or virus reduction.
A little more clarity

Good questions.
Straight answers.

Does a listed contaminant mean it is reduced?

This directory shows both source results and topics awaiting evidence. Only entries labelled “Source result” have a published measurement here. Other entries display “No published result” or “Not claimed”.

What about VOCs and the chemicals in that group?

Surrogate testing has been completed with positive results. See the attached report for the tested compound, test conditions, and scope of the findings.

Does Duryn One remove fluoride?

Yes. Duryn One reduces fluoride by >82%.

How often should I replace the cartridge?

Follow the current product guidance: 100 US gallons (approximately 379 litres) or 90 days of use, whichever comes first. Higher usage may require an earlier replacement. This replacement interval is not a statement that every contaminant has been tested through that volume.

Why are some results shown with a greater-than sign?

If the filtered concentration is below a laboratory reporting limit, the exact reduction cannot be calculated. We use that limit to show a conservative minimum. For example, a result reported as <5 ppt is not the same as zero.

Is “tested” the same as “certified”?

A laboratory report describes a specific sample under specified conditions. Certification applies to the products, components and claims covered by the certifying body’s official listing. Both the report and the listing should be read for their precise scope.

What would you like us to test next?

Tell us the contaminant or the question you want answered.

Suggest our next test